Price: $800 See Monthly Payments
We are selling our beer flow meter we purchased just a year and a half ago. This device has been absolutely amazing for us as we have been able to move this flow meter around onto any transfer pipe and measure liquid in gallons. We are able to measure mater going onto the mash, mash sugars going into the kettle, wort then going into the fermenter. Then measuring final product going into packaging. Allowing us to see liquid loss from start to finish. This comes with a plug and play system so you do not have to hardwire this into the electrical. Below are the details from the company. Gently used for a year. It is in perfect condition like new.
Specifications
Model
FD-H32
Type
Standard model
Supported pipe diameter
1″ (25A), ø28–37 ø1.10″-1.46″
1 1/4″ (32A), ø37–44 ø1.46″-1.73″
Supported pipe materials
Metal piping, hard plastic piping*1
Supported fluids
All fluids (water, oil, chemicals, etc.)*1
Supported fluid temperature
0–85°C 32–185°F (no freezing on pipe surface)*2
Maximum rated flow
1″ (25A) : 200 L/min 52.8 gal/min
1 1/4″ (32A) : 300 L/min 79.3 gal/min
Zero cut flow rate
1.0 L/min 0.3 gal/min (variable, initial value)
Detection principle
Delta TOF + Pulse Doppler
Function for automatic correction for speed of sound in liquid
Yes
Display
QVGA 2.0 model: color LCD, status indicator light
Display update cycle
Approx. 10 times/second
Display resolution
Instantaneous flow
0.01/0.1/1 (L/min) (default value: 1)
Integrated flow
0.01/0.1/1 (L) (default value: 1; up to 8 digits)
Response time
0.5 s / 1.0 s / 2.5 s / 5.0 s / 10.0 s / 30.0 s / 60.0 s / 120.0 s / 200.0 s
Measurement accuracy
Between 10 and 100% of F.S.: ±3.0% of RD*3*4
Between 0 and 10% of F.S.: ±0.3% of F.S.*3*4
Repeatability
0.5 s: ±1.0%, 1 s: ±0.7%, 2.5 s: ±0.45%, 5 s: ±0.3%, 10 s: ±0.2%, 30 s: ±0.15%, 60 s: ±0.1% of F.S.*3*5
Hysteresis
Variable
Flow units
L/min m3/h G/min
Pulse output increments (L)
0.02–999.99
Pipe temperature measurement accuracy
±2.0°C ±3.5°F (pipe temperature 0–50°C 32–122°F) , ±3.0°C ±5.4°F (pipe temperature 50–85°C 122–185°F) (ambient temperature of 25°C 77°F)*3
Network support
IO-Link*6
Heat calculation function
Unit
MJ/h kW kBTU/h*7
Display resolution
Instantaneous value (MJ/h): 0.01/0.1/1 (default value 0.1); Integrated value (MJ): 0.01/0.1/1 (default value 0.1)*7
Pulse output increments (MJ)
0.02–999.99*7
Data accumulation
Accumulation period
Approx. 1 year
Data reading
USB2.0
Power I/O connector
M12 8-pin connector (male)
I/O (switchable)
Output (Ch1/2/3/4)
Instantaneous flow mode / area mode / pulse output mode / integrated flow mode / bubble detection mode / error output
NPN/PNP setting switching, open collector output 30 VDC or less, max. 100 mA/Ch or less, residual voltage 2.5 V or less
Analog output (Ch1/2)
4–20 mA/0–20 mA (switchable), load resistance 500 Ω or less
External input (Ch2/3)
Integrated reset input / flow-rate zero input / zero-point adjustment input / bank input
Short circuit current: 1.5 mA or less; input time: 20 ms or more
Power supply
Power voltage
20–30 VDC, ripple (P-P) 10% included, Class 2/LPS
Current consumption
240 mA or less (when using flow sensor standalone; with analog output; excluding load current)*8
Protection circuit
Protection against reverse power connection, power supply surges, output short circuits, and output surges
Environmental resistance
Enclosure rating
IP65/67 (IEC 60529)*9
Ambient temperature
Sensor head: −20 to +60°C –4 to +140°F (no freezing); Display unit: −20 to +50°C –4 to +122°F (no freezing)*2
Relative humidity
35–85% RH (no condensation)
Vibration resistance
10–500 Hz; Power spectral density: 0.816 G2/Hz; X, Y and Z directions
Shock resistance
100 m/s2 (approx. 10 G), 16 ms pulses, 1000 times each for X, Y and Z axes
Material
Display unit
Body: PPS/PET/POM; Display window: PAR
Sensor head
Body: PPS/PET/PAR/SUS304
Sensor element: special rubber; Mounting bracket: SUS304/SUSXM7
Weight
approx. 620 g 21.87 oz